<?xml version="1.0" encoding="US-ASCII"?>
<!-- This template is for creating an Internet Draft using xml2rfc,
     which is available here: http://xml.resource.org. -->
<!DOCTYPE rfc SYSTEM "rfc2629.dtd">
<?xml-stylesheet type='text/xsl' href='rfc2629.xslt' ?>
<!-- used by XSLT processors -->
<!-- For a complete list and description of processing instructions (PIs), 
     please see http://xml.resource.org/authoring/README.html. -->
<!-- Below are generally applicable Processing Instructions (PIs) that most I-Ds might want to use.
     (Here they are set differently than their defaults in xml2rfc v1.32) -->
<?rfc strict="no" ?>
<!-- give errors regarding ID-nits and DTD validation -->
<!-- control the table of contents (ToC) -->
<?rfc toc="yes"?>
<!-- generate a ToC -->
<?rfc tocdepth="4"?>
<!-- the number of levels of subsections in ToC. default: 3 -->
<!-- control references -->
<?rfc symrefs="yes"?>
<!-- use symbolic references tags, i.e, [RFC2119] instead of [1] -->
<?rfc sortrefs="yes" ?>
<!-- sort the reference entries alphabetically -->
<!-- control vertical white space 
     (using these PIs as follows is recommended by the RFC Editor) -->
<?rfc compact="yes" ?>
<!-- do not start each main section on a new page -->
<?rfc subcompact="no" ?>
<!-- keep one blank line between list items -->
<!-- end of list of popular I-D processing instructions -->
<rfc category="info" docName="draft-ietf-nvo3-arch-07" ipr="trust200902">
  <!-- category values: std, bcp, info, exp, and historic
       ipr values: full3667, noModification3667, noDerivatives3667
       you can add the attributes updates="NNNN" and obsoletes="NNNN" 
       they will automatically be output with "(if approved)" -->

  <!-- ***** FRONT MATTER ***** -->

  <front>
    <!-- The abbreviated title is used in the page header - it is only necessary if the 
	 full title is longer than 39 characters -->

    <title abbrev="NVO3 Architecture">An Architecture for Data Center Network
    Virtualization Overlays (NVO3)</title>

    <!-- add 'role="editor"' below for the editors if appropriate -->

    <!-- Another author who claims to be an editor -->

    <author fullname="David Black" initials="D." surname="Black">
      <organization>EMC</organization>

      <address>
        <email>david.black@emc.com</email>
      </address>
    </author>

    <author fullname="Jon Hudson" initials="J." surname="Hudson">
      <organization>Independent</organization>

      <address>
        <email>jon.hudson@gmail.com</email>
      </address>
    </author>

    <author fullname="Lawrence Kreeger" initials="L." surname="Kreeger">
      <organization>Cisco</organization>

      <address>
        <email>kreeger@cisco.com</email>
      </address>
    </author>

    <author fullname="Marc Lasserre" initials="M." surname="Lasserre">
      <organization>Independent</organization>

      <address>
        <email>mmlasserre@gmail.com</email>
      </address>
    </author>

    <author fullname="Thomas Narten" initials="T." surname="Narten">
      <organization>IBM</organization>

      <address>
        <email>narten@us.ibm.com</email>
      </address>
    </author>

    <date month="August" year="2016"/>

    <!-- If the month and year are both specified and are the current ones, xml2rfc will fill 
	 in the current day for you. If only the current year is specified, xml2rfc will fill 
	 in the current day and month for you. If the year is not the current one, it is 
	 necessary to specify at least a month (xml2rfc assumes day="1" if not specified for the 
	 purpose of calculating the expiry date).  With drafts it is normally sufficient to 
	 specify just the year. -->

    <!-- Meta-data Declarations -->

    <area>General</area>

    <workgroup>Internet Engineering Task Force</workgroup>

    <!-- WG name at the upperleft corner of the doc,
	 IETF is fine for individual submissions.  
	 If this element is not present, the default is "Network Working Group",
	 which is used by the RFC Editor as a nod to the history of the IETF. -->

    <keyword>template</keyword>

    <!-- Keywords will be incorporated into HTML output
	 files in a meta tag but they have no effect on text or nroff
	 output. If you submit your draft to the RFC Editor, the
	 keywords will be used for the search engine. -->

    <abstract>
      <t>This document presents a high-level overview architecture for
      building data center network virtualization overlay (NVO3) networks. The
      architecture is given at a high-level, showing the major components of
      an overall system. An important goal is to divide the space into
      individual smaller components that can be implemented independently and
      with clear interfaces and interactions with other components. It should
      be possible to build and implement individual components in isolation
      and have them work with other components with no changes to other
      components. That way implementers have flexibility in implementing
      individual components and can optimize and innovate within their
      respective components without requiring changes to other components.</t>
    </abstract>
  </front>

  <middle>
    <section title="Introduction">
      <t>This document presents a high-level architecture for building data
      center network virtualization overlay (NVO3) networks. The architecture
      is given at a high-level, showing the major components of an overall
      system. An important goal is to divide the space into smaller individual
      components that can be implemented independently and with clear
      interfaces and interactions with other components. It should be possible
      to build and implement individual components in isolation and have them
      work with other components with no changes to other components. That way
      implementers have flexibility in implementing individual components and
      can optimize and innovate within their respective components without
      necessarily requiring changes to other components.</t>

      <t>The motivation for overlay networks is given in "Problem Statement:
      Overlays for Network Virtualization" <xref target="RFC7364"/>.
      "Framework for DC Network Virtualization" <xref target="RFC7365"/>
      provides a framework for discussing overlay networks generally and the
      various components that must work together in building such systems.
      This document differs from the framework document in that it doesn't
      attempt to cover all possible approaches within the general design
      space. Rather, it describes one particular approach that the NVO3 WG has
      focused on.</t>
    </section>

    <section title="Terminology">
      <t>This document uses the same terminology as <xref target="RFC7365"/>.
      In addition, the following terms are used:</t>

      <t><list style="hanging">
          <t hangText="NV Domain">A Network Virtualization Domain is an
          administrative construct that defines a Network Virtualization
          Authority (NVA), the set of Network Virtualization Edges (NVEs)
          associated with that NVA, and the set of virtual networks the NVA
          manages and supports. NVEs are associated with a (logically
          centralized) NVA, and an NVE supports communication for any of the
          virtual networks in the domain.</t>

          <t hangText="NV Region">A region over which information about a set
          of virtual networks is shared. The degenerate case of a single NV
          Domain corresponds to an NV region corresponding to that domain. The
          more interesting case occurs when two or more NV Domains share
          information about part or all of a set of virtual networks that they
          manage. Two NVAs share information about particular virtual networks
          for the purpose of supporting connectivity between tenants located
          in different NV Domains. NVAs can share information about an entire
          NV domain, or just individual virtual networks.</t>

          <t hangText="Tenant System Interface (TSI)">Interface to a Virtual
          Network as presented to a Tenant System. The TSI logically connects
          to the NVE via a Virtual Access Point (VAP). To the Tenant System,
          the TSI is like a Network Interface Card (NIC); the TSI presents
          itself to a Tenant System as a normal network interface.</t>

          <t hangText="VLAN">Unless stated otherwise, the terms VLAN and VLAN
          Tag are used in this document to denote a C-VLAN <xref
          target="IEEE-802.1Q"/> and the terms are used interchangeably to
          improve readability.</t>
        </list></t>
    </section>

    <section title="Background">
      <t>Overlay networks are an approach for providing network virtualization
      services to a set of Tenant Systems (TSs) <xref target="RFC7365"/>. With
      overlays, data traffic between tenants is tunneled across the underlying
      data center's IP network. The use of tunnels provides a number of
      benefits by decoupling the network as viewed by tenants from the
      underlying physical network across which they communicate.</t>

      <t>Tenant Systems connect to Virtual Networks (VNs), with each VN having
      associated attributes defining properties of the network, such as the
      set of members that connect to it. Tenant Systems connected to a virtual
      network typically communicate freely with other Tenant Systems on the
      same VN, but communication between Tenant Systems on one VN and those
      external to the VN (whether on another VN or connected to the Internet)
      is carefully controlled and governed by policy. The NVO3 architecture
      does not impose any restrictions to the application of policy controls
      even within a VN.</t>

      <t>A Network Virtualization Edge (NVE) <xref target="RFC7365"/> is the
      entity that implements the overlay functionality. An NVE resides at the
      boundary between a Tenant System and the overlay network as shown in
      <xref target="nvo3-reference-model"/>. An NVE creates and maintains
      local state about each Virtual Network for which it is providing service
      on behalf of a Tenant System.</t>

      <figure anchor="nvo3-reference-model"
              title="NVO3 Generic  Reference Model">
        <artwork name="nvo3-reference-model"><![CDATA[
     
    +--------+                                             +--------+ 
    | Tenant +--+                                     +----| Tenant | 
    | System |  |                                    (')   | System | 
    +--------+  |          ................         (   )  +--------+ 
                |  +-+--+  .              .  +--+-+  (_)     
                |  | NVE|--.              .--| NVE|   | 
                +--|    |  .              .  |    |---+ 
                   +-+--+  .              .   +--+-+
                   /       .              .  
                  /        .  L3 Overlay  .   +--+-++--------+ 
    +--------+   /         .    Network   .   | NVE|| Tenant | 
    | Tenant +--+          .              .- -|    || System | 
    | System |             .              .   +--+-++--------+ 
    +--------+             ................
                                  |
                                +----+
                                | NVE| 
                                |    | 
                                +----+ 
                                  |       
                                  | 
                        ===================== 
                          |               | 
                      +--------+      +--------+ 
                      | Tenant |      | Tenant | 
                      | System |      | System | 
                      +--------+      +--------+ 
    
         ]]></artwork>
      </figure>

      <t>The following subsections describe key aspects of an overlay system
      in more detail. <xref target="nvo3-service"/> describes the service
      model (Ethernet vs. IP) provided to Tenant Systems. <xref
      target="nve-section"/> describes NVEs in more detail. <xref
      target="nva-intro"/> introduces the Network Virtualization Authority,
      from which NVEs obtain information about virtual networks. <xref
      target="background-orchestration"/> provides background on Virtual
      Machine (VM) orchestration systems and their use of virtual
      networks.</t>

      <section anchor="nvo3-service" title="VN Service (L2 and L3)">
        <t>A Virtual Network provides either L2 or L3 service to connected
        tenants. For L2 service, VNs transport Ethernet frames, and a Tenant
        System is provided with a service that is analogous to being connected
        to a specific L2 C-VLAN. L2 broadcast frames are generally delivered
        to all (and multicast frames delivered to a subset of) the other
        Tenant Systems on the VN. To a Tenant System, it appears as if they
        are connected to a regular L2 Ethernet link. Within the NVO3
        architecture, tenant frames are tunneled to remote NVEs based on the
        MAC addresses of the frame headers as originated by the Tenant System.
        On the underlay, NVO3 packets are forwarded between NVEs based on the
        outer addresses of tunneled packets.</t>

        <t>For L3 service, VNs transport IP datagrams, and a Tenant System is
        provided with a service that only supports IP traffic. Within the NVO3
        architecture, tenant frames are tunneled to remote NVEs based on the
        IP addresses of the packet originated by the Tenant System; any L2
        destination addresses provided by Tenant Systems are effectively
        ignored by the NVEs and overlay network. For L3 service, the Tenant
        System will be configured with an IP subnet that is effectively a
        point-to-point link, i.e., having only the Tenant System and a
        next-hop router address on it.</t>

        <t>L2 service is intended for systems that need native L2 Ethernet
        service and the ability to run protocols directly over Ethernet (i.e.,
        not based on IP). L3 service is intended for systems in which all the
        traffic can safely be assumed to be IP. It is important to note that
        whether an NVO3 network provides L2 or L3 service to a Tenant System,
        the Tenant System does not generally need to be aware of the
        distinction. In both cases, the virtual network presents itself to the
        Tenant System as an L2 Ethernet interface. An Ethernet interface is
        used in both cases simply as a widely supported interface type that
        essentially all Tenant Systems already support. Consequently, no
        special software is needed on Tenant Systems to use an L3 vs. an L2
        overlay service.</t>

        <t>NVO3 can also provide a combined L2 and L3 service to tenants. A
        combined service provides L2 service for intra-VN communication, but
        also provides L3 service for L3 traffic entering or leaving the VN.
        Architecturally, the handling of a combined L2/L3 service within the
        NVO3 architecture is intended to match what is commonly done today in
        non-overlay environments by devices providing a combined bridge/router
        service. With combined service, the virtual network itself retains the
        semantics of L2 service and all traffic is processed according to its
        L2 semantics. In addition, however, traffic requiring IP processing is
        also processed at the IP level.</t>

        <t>The IP processing for a combined service can be implemented on a
        standalone device attached to the virtual network (e.g., an IP router)
        or implemented locally on the NVE (see Section 5.4 on Distributed
        Gateways). For unicast traffic, NVE implementation of a combined
        service may result in a packet being delivered to another TS attached
        to the same NVE (on either the same or a different VN) or tunneled to
        a remote NVE, or even forwarded outside the NV domain. For multicast
        or broadcast packets, the combination of NVE L2 and L3 processing may
        result in copies of the packet receiving both L2 and L3 treatments to
        realize delivery to all of the destinations involved. This distributed
        NVE implementation of IP routing results in the same network delivery
        behavior as if the L2 processing of the packet included delivery of
        the packet to an IP router attached to the L2 VN as a TS, with the
        router having additional network attachments to other networks, either
        virtual or not.</t>

        <section anchor="vlan-tags-section" title="VLAN Tags in L2 Service">
          <t>An NVO3 L2 virtual network service may include encapsulated L2
          VLAN tags provided by a Tenant System, but does not use encapsulated
          tags in deciding where and how to forward traffic. Such VLAN tags
          can be passed through, so that Tenant Systems that send or expect to
          receive them can be supported as appropriate.</t>

          <t>The processing of VLAN tags that an NVE receives from a TS is
          controlled by settings associated with the VAP. Just as in the case
          with ports on Ethernet switches, a number of settings are possible.
          For example, C-TAGs can be passed through transparently, they could
          always be stripped upon receipt from a Tenant System, they could be
          compared against a list of explicitly configured tags, etc.</t>

          <t>Note that that there are additional considerations when VLAN tags
          are used to identify both the VN and a Tenant System VLAN within
          that VN, as described in <xref target="vlan-tags-split-nve"/>
          below.</t>
        </section>

        <section anchor="packet-lifetime-considerations"
                 title="Packet Lifetime Considerations">
          <t>For L3 service, Tenant Systems should expect the IPv4 TTL (Time
          to Live) or IPv6 Hop Limit in the packets they send to be
          decremented by at least 1. For L2 service, neither the TTL nor the
          Hop Limit (when the packet is IP) are modified. The underlay network
          manages TTLs and Hop Limits in the outer IP encapsulation - the
          values in these fields could be independent from or related to the
          values in the same fields of tenant IP packets.</t>
        </section>
      </section>

      <section anchor="nve-section" title="Network Virtualization Edge (NVE)">
        <t>Tenant Systems connect to NVEs via a Tenant System Interface (TSI).
        The TSI logically connects to the NVE via a Virtual Access Point (VAP)
        and each VAP is associated with one Virtual Network as shown in <xref
        target="nve-reference-model"/>. To the Tenant System, the TSI is like
        a NIC; the TSI presents itself to a Tenant System as a normal network
        interface. On the NVE side, a VAP is a logical network port (virtual
        or physical) into a specific virtual network. Note that two different
        Tenant Systems (and TSIs) attached to a common NVE can share a VAP
        (e.g., TS1 and TS2 in <xref target="nve-reference-model"/>) so long as
        they connect to the same Virtual Network.</t>

        <figure anchor="nve-reference-model" title="NVE Reference Model">
          <artwork name="nve-reference-model"><![CDATA[

                 |         Data Center Network (IP)        |
                 |                                         |
                 +-----------------------------------------+
                      |                           |
                      |       Tunnel Overlay      |
         +------------+---------+       +---------+------------+ 
         | +----------+-------+ |       | +-------+----------+ | 
         | |  Overlay Module  | |       | |  Overlay Module  | | 
         | +---------+--------+ |       | +---------+--------+ | 
         |           |          |       |           |          | 
  NVE1   |           |          |       |           |          | NVE2
         |  +--------+-------+  |       |  +--------+-------+  | 
         |  | VNI1      VNI2 |  |       |  | VNI1      VNI2 |  | 
         |  +-+----------+---+  |       |  +-+-----------+--+  | 
         |    | VAP1     | VAP2 |       |    | VAP1      | VAP2|
         +----+----------+------+       +----+-----------+-----+ 
              |          |                   |           | 
              |\         |                   |           |
              | \        |                   |          /| 
       -------+--\-------+-------------------+---------/-+------- 
              |   \      |     Tenant        |        /  |  
         TSI1 |TSI2\     | TSI3            TSI1  TSI2/   TSI3
             +---+ +---+ +---+             +---+ +---+   +---+ 
             |TS1| |TS2| |TS3|             |TS4| |TS5|   |TS6|
             +---+ +---+ +---+             +---+ +---+   +---+ 
         ]]></artwork>
        </figure>

        <t>The Overlay Module performs the actual encapsulation and
        decapsulation of tunneled packets. The NVE maintains state about the
        virtual networks it is a part of so that it can provide the Overlay
        Module with such information as the destination address of the NVE to
        tunnel a packet to and the Context ID that should be placed in the
        encapsulation header to identify the virtual network that a tunneled
        packet belongs to.</t>

        <t>On the data center network side, the NVE sends and receives native
        IP traffic. When ingressing traffic from a Tenant System, the NVE
        identifies the egress NVE to which the packet should be sent, adds an
        overlay encapsulation header, and sends the packet on the underlay
        network. When receiving traffic from a remote NVE, an NVE strips off
        the encapsulation header, and delivers the (original) packet to the
        appropriate Tenant System. When the source and destination Tenant
        System are on the same NVE, no encapsulation is needed and the NVE
        forwards traffic directly.</t>

        <t>Conceptually, the NVE is a single entity implementing the NVO3
        functionality. In practice, there are a number of different
        implementation scenarios, as described in detail in <xref
        target="nve-section2"/>.</t>
      </section>

      <section anchor="nva-intro"
               title="Network Virtualization Authority (NVA)">
        <t>Address dissemination refers to the process of learning, building
        and distributing the mapping/forwarding information that NVEs need in
        order to tunnel traffic to each other on behalf of communicating
        Tenant Systems. For example, in order to send traffic to a remote
        Tenant System, the sending NVE must know the destination NVE for that
        Tenant System.</t>

        <t>One way to build and maintain mapping tables is to use learning, as
        802.1 bridges do <xref target="IEEE-802.1Q"/>. When forwarding traffic
        to multicast or unknown unicast destinations, an NVE could simply
        flood traffic. While flooding works, it can lead to traffic hot spots
        and can lead to problems in larger networks (e.g., excessive amounts
        of flooded traffic).</t>

        <t>Alternatively, to reduce the scope of where flooding must take
        place, or to eliminate it all together, NVEs can make use of a Network
        Virtualization Authority (NVA). An NVA is the entity that provides
        address mapping and other information to NVEs. NVEs interact with an
        NVA to obtain any required address mapping information they need in
        order to properly forward traffic on behalf of tenants. The term NVA
        refers to the overall system, without regards to its scope or how it
        is implemented. NVAs provide a service, and NVEs access that service
        via an NVE-to-NVA protocol as discussed in <xref
        target="nve-to-nva"/>.</t>

        <t>Even when an NVA is present, Ethernet bridge MAC address learning
        could be used as a fallback mechanism, should the NVA be unable to
        provide an answer or for other reasons. This document does not
        consider flooding approaches in detail, as there are a number of
        benefits in using an approach that depends on the presence of an
        NVA.</t>

        <t>For the rest of this document, it is assumed that an NVA exists and
        will be used. NVAs are discussed in more detail in <xref
        target="nva-section"/>.</t>
      </section>

      <section anchor="background-orchestration"
               title="VM Orchestration Systems">
        <t>VM orchestration systems manage server virtualization across a set
        of servers. Although VM management is a separate topic from network
        virtualization, the two areas are closely related. Managing the
        creation, placement, and movement of VMs also involves creating,
        attaching to and detaching from virtual networks. A number of existing
        VM orchestration systems have incorporated aspects of virtual network
        management into their systems.</t>

        <t>Note also, that although this section uses the term "VM" and
        "hypervisor" throughout, the same issues apply to other virtualization
        approaches, including Linux Containers (LXC), BSD Jails, Network
        Service Appliances as discussed in Section 5.1, etc.. From an NVO3
        perspective, it should be assumed that where the document uses the
        term "VM" and "hypervisor", the intention is that the discussion also
        applies to other systems, where, e.g., the host operating system plays
        the role of the hypervisor in supporting virtualization, and a
        container plays the equivalent role as a VM.</t>

        <t>When a new VM image is started, the VM orchestration system
        determines where the VM should be placed, interacts with the
        hypervisor on the target server to load and start the VM and controls
        when a VM should be shutdown or migrated elsewhere. VM orchestration
        systems also have knowledge about how a VM should connect to a
        network, possibly including the name of the virtual network to which a
        VM is to connect. The VM orchestration system can pass such
        information to the hypervisor when a VM is instantiated. VM
        orchestration systems have significant (and sometimes global)
        knowledge over the domain they manage. They typically know on what
        servers a VM is running, and meta data associated with VM images can
        be useful from a network virtualization perspective. For example, the
        meta data may include the addresses (MAC and IP) the VMs will use and
        the name(s) of the virtual network(s) they connect to.</t>

        <t>VM orchestration systems run a protocol with an agent running on
        the hypervisor of the servers they manage. That protocol can also
        carry information about what virtual network a VM is associated with.
        When the orchestrator instantiates a VM on a hypervisor, the
        hypervisor interacts with the NVE in order to attach the VM to the
        virtual networks it has access to. In general, the hypervisor will
        need to communicate significant VM state changes to the NVE. In the
        reverse direction, the NVE may need to communicate network
        connectivity information back to the hypervisor. Examples of deployed
        VM orchestration systems include VMware's vCenter Server, Microsoft's
        System Center Virtual Machine Manager, and systems based on OpenStack
        and its associated plugins (e.g., Nova and Neutron). Each can pass
        information about what virtual networks a VM connects to down to the
        hypervisor. The protocol used between the VM orchestration system and
        hypervisors is generally proprietary.</t>

        <t>It should be noted that VM orchestration systems may not have
        direct access to all networking related information a VM uses. For
        example, a VM may make use of additional IP or MAC addresses that the
        VM management system is not aware of.</t>
      </section>
    </section>

    <section anchor="nve-section2" title="Network Virtualization Edge (NVE)">
      <t>As introduced in <xref target="nve-section"/> an NVE is the entity
      that implements the overlay functionality. This section describes NVEs
      in more detail. An NVE will have two external interfaces:</t>

      <t><list style="hanging">
          <t hangText="Tenant System Facing:">On the Tenant System facing
          side, an NVE interacts with the hypervisor (or equivalent entity) to
          provide the NVO3 service. An NVE will need to be notified when a
          Tenant System "attaches" to a virtual network (so it can validate
          the request and set up any state needed to send and receive traffic
          on behalf of the Tenant System on that VN). Likewise, an NVE will
          need to be informed when the Tenant System "detaches" from the
          virtual network so that it can reclaim state and resources
          appropriately.</t>

          <t hangText="Data Center Network Facing:">On the data center network
          facing side, an NVE interfaces with the data center underlay
          network, sending and receiving tunneled packets to and from the
          underlay. The NVE may also run a control protocol with other
          entities on the network, such as the Network Virtualization
          Authority.</t>
        </list></t>

      <section title="NVE Co-located With Server Hypervisor">
        <t>When server virtualization is used, the entire NVE functionality
        will typically be implemented as part of the hypervisor and/or virtual
        switch on the server. In such cases, the Tenant System interacts with
        the hypervisor and the hypervisor interacts with the NVE. Because the
        interaction between the hypervisor and NVE is implemented entirely in
        software on the server, there is no "on-the-wire" protocol between
        Tenant Systems (or the hypervisor) and the NVE that needs to be
        standardized. While there may be APIs between the NVE and hypervisor
        to support necessary interaction, the details of such an API are not
        in-scope for the NVO3 WG at the time of publication of this memo.</t>

        <t>Implementing NVE functionality entirely on a server has the
        disadvantage that server CPU resources must be spent implementing the
        NVO3 functionality. Experimentation with overlay approaches and
        previous experience with TCP and checksum adapter offloads suggests
        that offloading certain NVE operations (e.g., encapsulation and
        decapsulation operations) onto the physical network adapter can
        produce performance advantages. As has been done with checksum and/or
        TCP server offload and other optimization approaches, there may be
        benefits to offloading common operations onto adapters where possible.
        Just as important, the addition of an overlay header can disable
        existing adapter offload capabilities that are generally not prepared
        to handle the addition of a new header or other operations associated
        with an NVE.</t>

        <t>While the exact details of how to split the implementation of
        specific NVE functionality between a server and its network adapters
        is an implementation matter and outside the scope of IETF
        standardization, the NVO3 architecture should be cognizant of and
        support such separation. Ideally, it may even be possible to bypass
        the hypervisor completely on critical data path operations so that
        packets between a TS and its VN can be sent and received without
        having the hypervisor involved in each individual packet
        operation.</t>
      </section>

      <section anchor="split-nve" title="Split-NVE">
        <t>Another possible scenario leads to the need for a split NVE
        implementation. An NVE running on a server (e.g. within a hypervisor)
        could support NVO3 service towards the tenant, but not perform all NVE
        functions (e.g., encapsulation) directly on the server; some of the
        actual NVO3 functionality could be implemented on (i.e., offloaded to)
        an adjacent switch to which the server is attached. While one could
        imagine a number of link types between a server and the NVE, one
        simple deployment scenario would involve a server and NVE separated by
        a simple L2 Ethernet link. A more complicated scenario would have the
        server and NVE separated by a bridged access network, such as when the
        NVE resides on a ToR, with an embedded switch residing between servers
        and the ToR.</t>

        <t>For the split NVE case, protocols will be needed that allow the
        hypervisor and NVE to negotiate and setup the necessary state so that
        traffic sent across the access link between a server and the NVE can
        be associated with the correct virtual network instance. Specifically,
        on the access link, traffic belonging to a specific Tenant System
        would be tagged with a specific VLAN C-TAG that identifies which
        specific NVO3 virtual network instance it connects to. The
        hypervisor-NVE protocol would negotiate which VLAN C-TAG to use for a
        particular virtual network instance. More details of the protocol
        requirements for functionality between hypervisors and NVEs can be
        found in <xref target="I-D.ietf-nvo3-nve-nva-cp-req"/>.</t>

        <section anchor="vlan-tags-split-nve"
                 title="Tenant VLAN handling in Split-NVE Case">
          <t>Preserving tenant VLAN tags across an NVO3 VN as described in
          <xref target="vlan-tags-section"/> poses additional complications in
          the split-NVE case. The portion of the NVE that performs the
          encapsulation function needs access to the specific VLAN tags that
          the Tenant System is using in order to include them in the
          encapsulated packet. When an NVE is implemented entirely within the
          hypervisor, the NVE has access to the complete original packet
          (including any VLAN tags) sent by the tenant. In the split-NVE case,
          however, the VLAN tag used between the hypervisor and offloaded
          portions of the NVE normally only identify the specific VN that
          traffic belongs to. In order to allow a tenant to preserve VLAN
          information from end to end between TS when in the split-NVE case,
          additional mechanisms would be needed (e.g., carry an additional
          VLAN tag by carrying both a C-Tag and an S-Tag as specified in <xref
          target="IEEE-802.1Q"/> where the C-Tag identifies the TS VLAN
          end-to-end and the S-Tag identifies the VN locally between each TS
          and the corresponding NVE).</t>
        </section>
      </section>

      <section anchor="nve-state" title="NVE State">
        <t>NVEs maintain internal data structures and state to support the
        sending and receiving of tenant traffic. An NVE may need some or all
        of the following information:</t>

        <t><list style="numbers">
            <t>An NVE keeps track of which attached Tenant Systems are
            connected to which virtual networks. When a Tenant System attaches
            to a virtual network, the NVE will need to create or update local
            state for that virtual network. When the last Tenant System
            detaches from a given VN, the NVE can reclaim state associated
            with that VN.</t>

            <t>For tenant unicast traffic, an NVE maintains a per-VN table of
            mappings from Tenant System (inner) addresses to remote NVE
            (outer) addresses.</t>

            <t>For tenant multicast (or broadcast) traffic, an NVE maintains a
            per-VN table of mappings and other information on how to deliver
            tenant multicast (or broadcast) traffic. If the underlying network
            supports IP multicast, the NVE could use IP multicast to deliver
            tenant traffic. In such a case, the NVE would need to know what IP
            underlay multicast address to use for a given VN. Alternatively,
            if the underlying network does not support multicast, a source NVE
            could use unicast replication to deliver traffic. In such a case,
            an NVE would need to know which remote NVEs are participating in
            the VN. An NVE could use both approaches, switching from one mode
            to the other depending on such factors as bandwidth efficiency and
            group membership sparseness. <xref
            target="I-D.ietf-nvo3-mcast-framework"/> discusses the subject of
            multicast handling in NVO3 in further detail.</t>

            <t>An NVE maintains necessary information to encapsulate outgoing
            traffic, including what type of encapsulation and what value to
            use for a Context ID to identify the VN within the encapsulation
            header.</t>

            <t>In order to deliver incoming encapsulated packets to the
            correct Tenant Systems, an NVE maintains the necessary information
            to map incoming traffic to the appropriate VAP (i.e., Tenant
            System Interface).</t>

            <t>An NVE may find it convenient to maintain additional per-VN
            information such as QoS settings, Path MTU information, ACLs,
            etc.</t>
          </list></t>
      </section>

      <section anchor="multi-homing" title="Multi-Homing of NVEs">
        <t>NVEs may be multi-homed. That is, an NVE may have more than one IP
        address associated with it on the underlay network. Multihoming
        happens in two different scenarios. First, an NVE may have multiple
        interfaces connecting it to the underlay. Each of those interfaces
        will typically have a different IP address, resulting in a specific
        Tenant Address (on a specific VN) being reachable through the same NVE
        but through more than one underlay IP address. Second, a specific
        tenant system may be reachable through more than one NVE, each having
        one or more underlay addresses. In both cases, NVE address mapping
        functionality needs to support one-to-many mappings and enable a
        sending NVE to (at a minimum) be able to fail over from one IP address
        to another, e.g., should a specific NVE underlay address become
        unreachable.</t>

        <t>Finally, multi-homed NVEs introduce complexities when source
        unicast replication is used to implement tenant multicast as described
        in Section 4.3. Specifically, an NVE should only receive one copy of a
        replicated packet.</t>

        <t>Multi-homing is needed to support important use cases. First, a
        bare metal server may have multiple uplink connections to either the
        same or different NVEs. Having only a single physical path to an
        upstream NVE, or indeed, having all traffic flow through a single NVE
        would be considered unacceptable in highly-resilient deployment
        scenarios that seek to avoid single points of failure. Moreover, in
        today's networks, the availability of multiple paths would require
        that they be usable in an active-active fashion (e.g., for load
        balancing).</t>
      </section>

      <section anchor="vap-error" title="VAP">
        <t>The VAP is the NVE-side of the interface between the NVE and the
        TS. Traffic to and from the tenant flows through the VAP. If an NVE
        runs into difficulties sending traffic received on the VAP, it may
        need to signal such errors back to the VAP. Because the VAP is an
        emulation of a physical port, its ability to signal NVE errors is
        limited and lacks sufficient granularity to reflect all possible
        errors an NVE may encounter (e.g., inability reach a particular
        destination). Some errors, such as an NVE losing all of its
        connections to the underlay, could be reflected back to the VAP by
        effectively disabling it. This state change would reflect itself on
        the TS as an interface going down, allowing the TS to implement
        interface error handling, e.g., failover, in the same manner as when a
        physical interfaces becomes disabled.</t>
      </section>
    </section>

    <section title="Tenant System Types">
      <t>This section describes a number of special Tenant System types and
      how they fit into an NVO3 system.</t>

      <section anchor="data-appliance"
               title="Overlay-Aware Network Service Appliances">
        <t>Some Network Service Appliances <xref
        target="I-D.ietf-nvo3-nve-nva-cp-req"/> (virtual or physical) provide
        tenant-aware services. That is, the specific service they provide
        depends on the identity of the tenant making use of the service. For
        example, firewalls are now becoming available that support
        multi-tenancy where a single firewall provides virtual firewall
        service on a per-tenant basis, using per-tenant configuration rules
        and maintaining per-tenant state. Such appliances will be aware of the
        VN an activity corresponds to while processing requests. Unlike server
        virtualization, which shields VMs from needing to know about
        multi-tenancy, a Network Service Appliance may explicitly support
        multi-tenancy. In such cases, the Network Service Appliance itself
        will be aware of network virtualization and either embed an NVE
        directly, or implement a split NVE as described in <xref
        target="split-nve"/>. Unlike server virtualization, however, the
        Network Service Appliance may not be running a hypervisor and the VM
        orchestration system may not interact with the Network Service
        Appliance. The NVE on such appliances will need to support a control
        plane to obtain the necessary information needed to fully participate
        in an NV Domain.</t>
      </section>

      <section title="Bare Metal Servers">
        <t>Many data centers will continue to have at least some servers
        operating as non-virtualized (or "bare metal") machines running a
        traditional operating system and workload. In such systems, there will
        be no NVE functionality on the server, and the server will have no
        knowledge of NVO3 (including whether overlays are even in use). In
        such environments, the NVE functionality can reside on the first-hop
        physical switch. In such a case, the network administrator would
        (manually) configure the switch to enable the appropriate NVO3
        functionality on the switch port connecting the server and associate
        that port with a specific virtual network. Such configuration would
        typically be static, since the server is not virtualized, and once
        configured, is unlikely to change frequently. Consequently, this
        scenario does not require any protocol or standards work.</t>
      </section>

      <section title="Gateways">
        <t>Gateways on VNs relay traffic onto and off of a virtual network.
        Tenant Systems use gateways to reach destinations outside of the local
        VN. Gateways receive encapsulated traffic from one VN, remove the
        encapsulation header, and send the native packet out onto the data
        center network for delivery. Outside traffic enters a VN in a reverse
        manner.</t>

        <t>Gateways can be either virtual (i.e., implemented as a VM) or
        physical (i.e., as a standalone physical device). For performance
        reasons, standalone hardware gateways may be desirable in some cases.
        Such gateways could consist of a simple switch forwarding traffic from
        a VN onto the local data center network, or could embed router
        functionality. On such gateways, network interfaces connecting to
        virtual networks will (at least conceptually) embed NVE (or split-NVE)
        functionality within them. As in the case with Network Service
        Appliances, gateways may not support a hypervisor and will need an
        appropriate control plane protocol to obtain the information needed to
        provide NVO3 service.</t>

        <t>Gateways handle several different use cases. For example, one use
        case consists of systems supporting overlays together with systems
        that do not (e.g., bare metal servers). Gateways could be used to
        connect legacy systems supporting, e.g., L2 VLANs, to specific virtual
        networks, effectively making them part of the same virtual network.
        Gateways could also forward traffic between a virtual network and
        other hosts on the data center network or relay traffic between
        different VNs. Finally, gateways can provide external connectivity
        such as Internet or VPN access.</t>

        <section title="Gateway Taxonomy">
          <t>As can be seen from the discussion above, there are several types
          of gateways that can exist in an NVO3 environment. This section
          breaks them down into the various types that could be supported.
          Note that each of the types below could be implemented in either a
          centralized manner or distributed to co-exist with the NVEs.</t>

          <section title="L2 Gateways (Bridging)">
            <t>L2 Gateways act as layer 2 bridges to forward Ethernet frames
            based on the MAC addresses present in them.</t>

            <t><list hangIndent="6" style="hanging">
                <t hangText="L2 VN to Legacy L2:">This type of gateway bridges
                traffic between L2 VNs and other legacy L2 networks such as
                VLANs or L2 VPNs.</t>

                <t hangText="L2 VN to L2 VN:">The main motivation for this
                type of gateway to create separate groups of Tenant Systems
                using L2 VNs such that the gateway can enforce network
                policies between each L2 VN.</t>
              </list></t>
          </section>

          <section title="L3 Gateways (Only IP Packets)">
            <t>L3 Gateways forward IP packets based on the IP addresses
            present in the packets.</t>

            <t><list hangIndent="6" style="hanging">
                <t hangText="L3 VN to Legacy L2:">This type of gateway
                forwards packets on between L3 VNs and legacy L2 networks such
                as VLANs or L2 VPNs. The MAC address in any frames forwarded
                between the legacy L2 network would be the MAC address of the
                gateway.</t>

                <t hangText="L3 VN to Legacy L3:">The type of gateway forwards
                packets between L3 VNs and legacy L3 networks. These legacy L3
                networks could be local the data center, in the WAN, or an L3
                VPN.</t>

                <t hangText="L3 VN to L2 VN:">This type of gateway forwards
                packets on between L3 VNs and L2 VNs. The MAC address in any
                frames forwarded between the L2 VN would be the MAC address of
                the gateway.</t>

                <t hangText="L2 VN to L2 VN:">This type of gateway acts
                similar to a traditional router that forwards between L2
                interfaces. The MAC address in any frames forwarded between
                the L2 VNs would be the MAC address of the gateway.</t>

                <t hangText="L3 VN to L3 VN:">The main motivation for this
                type of gateway to create separate groups of Tenant Systems
                using L3 VNs such that the gateway can enforce network
                policies between each L3 VN.</t>
              </list></t>
          </section>
        </section>
      </section>

      <section title="Distributed Inter-VN Gateways">
        <t>The relaying of traffic from one VN to another deserves special
        consideration. Whether traffic is permitted to flow from one VN to
        another is a matter of policy, and would not (by default) be allowed
        unless explicitly enabled. In addition, NVAs are the logical place to
        maintain policy information about allowed inter-VN communication.
        Policy enforcement for inter-VN communication can be handled in (at
        least) two different ways. Explicit gateways could be the central
        point for such enforcement, with all inter-VN traffic forwarded to
        such gateways for processing. Alternatively, the NVA can provide such
        information directly to NVEs, by either providing a mapping for a
        target TS on another VN, or indicating that such communication is
        disallowed by policy.</t>

        <t>When inter-VN gateways are centralized, traffic between TSs on
        different VNs can take suboptimal paths, i.e., triangular routing
        results in paths that always traverse the gateway. In the worst case,
        traffic between two TSs connected to the same NVE can be hair-pinned
        through an external gateway. As an optimization, individual NVEs can
        be part of a distributed gateway that performs such relaying, reducing
        or completely eliminating triangular routing. In a distributed
        gateway, each ingress NVE can perform such relaying activity directly,
        so long as it has access to the policy information needed to determine
        whether cross-VN communication is allowed. Having individual NVEs be
        part of a distributed gateway allows them to tunnel traffic directly
        to the destination NVE without the need to take suboptimal paths.</t>

        <t>The NVO3 architecture supports distributed gateways for the case of
        inter-VN communication. Such support requires that NVO3 control
        protocols include mechanisms for the maintenance and distribution of
        policy information about what type of cross-VN communication is
        allowed so that NVEs acting as distributed gateways can tunnel traffic
        from one VN to another as appropriate.</t>

        <t>Distributed gateways could also be used to distribute other
        traditional router services to individual NVEs. The NVO3 architecture
        does not preclude such implementations, but does not define or require
        them as they are outside the scope of the NVO3 architecture.</t>
      </section>

      <section anchor="arp-and-nd" title="ARP and Neighbor Discovery">
        <t>For an L2 service, strictly speaking, special processing of Address
        Resolution Protocol (ARP) <xref target="RFC0826"/> (and IPv6 Neighbor
        Discovery (ND) <xref target="RFC4861"/>) is not required. ARP requests
        are broadcast, and an NVO3 can deliver ARP requests to all members of
        a given L2 virtual network, just as it does for any packet sent to an
        L2 broadcast address. Similarly, ND requests are sent via IP
        multicast, which NVO3 can support by delivering via L2 multicast.
        However, as a performance optimization, an NVE can intercept ARP (or
        ND) requests from its attached TSs and respond to them directly using
        information in its mapping tables. Since an NVE will have mechanisms
        for determining the NVE address associated with a given TS, the NVE
        can leverage the same mechanisms to suppress sending ARP and ND
        requests for a given TS to other members of the VN. The NVO3
        architecture supports such a capability.</t>
      </section>
    </section>

    <section anchor="nve-to-nve" title="NVE-NVE Interaction">
      <t>Individual NVEs will interact with each other for the purposes of
      tunneling and delivering traffic to remote TSs. At a minimum, a control
      protocol may be needed for tunnel setup and maintenance. For example,
      tunneled traffic may need to be encrypted or integrity protected, in
      which case it will be necessary to set up appropriate security
      associations between NVE peers. It may also be desirable to perform
      tunnel maintenance (e.g., continuity checks) on a tunnel in order to
      detect when a remote NVE becomes unreachable. Such generic tunnel setup
      and maintenance functions are not generally NVO3-specific. Hence, the
      NVO3 architecture expects to leverage existing tunnel maintenance
      protocols rather than defining new ones.</t>

      <t>Some NVE-NVE interactions may be specific to NVO3 (and in particular
      be related to information kept in mapping tables) and agnostic to the
      specific tunnel type being used. For example, when tunneling traffic for
      TS-X to a remote NVE, it is possible that TS-X is not presently
      associated with the remote NVE. Normally, this should not happen, but
      there could be race conditions where the information an NVE has learned
      from the NVA is out-of-date relative to actual conditions. In such
      cases, the remote NVE could return an error or warning indication,
      allowing the sending NVE to attempt a recovery or otherwise attempt to
      mitigate the situation.</t>

      <t>The NVE-NVE interaction could signal a range of indications, for
      example:</t>

      <t><list style="symbols">
          <t>"No such TS here", upon a receipt of a tunneled packet for an
          unknown TS.</t>

          <t>"TS-X not here, try the following NVE instead" (i.e., a
          redirect).</t>

          <t>Delivered to correct NVE, but could not deliver packet to TS-X
          (soft error).</t>

          <t>Delivered to correct NVE, but could not deliver packet to TS-X
          (hard error).</t>
        </list></t>

      <t>When an NVE receives information from a remote NVE that conflicts
      with the information it has in its own mapping tables, it should consult
      with the NVA to resolve those conflicts. In particular, it should
      confirm that the information it has is up-to-date, and it might indicate
      the error to the NVA, so as to nudge the NVA into following up (as
      appropriate). While it might make sense for an NVE to update its mapping
      table temporarily in response to an error from a remote NVE, any changes
      must be handled carefully as doing so can raise security considerations
      if the received information cannot be authenticated. That said, a
      sending NVE might still take steps to mitigate a problem, such as
      applying rate limiting to data traffic towards a particular NVE or
      TS.</t>
    </section>

    <section anchor="nva-section" title="Network Virtualization Authority">
      <t>Before sending to and receiving traffic from a virtual network, an
      NVE must obtain the information needed to build its internal forwarding
      tables and state as listed in <xref target="nve-state"/>. An NVE can
      obtain such information from a Network Virtualization Authority.</t>

      <t>The Network Virtualization Authority (NVA) is the entity that is
      expected to provide address mapping and other information to NVEs. NVEs
      can interact with an NVA to obtain any required information they need in
      order to properly forward traffic on behalf of tenants. The term NVA
      refers to the overall system, without regards to its scope or how it is
      implemented.</t>

      <section title="How an NVA Obtains Information">
        <t>There are two primary ways in which an NVA can obtain the address
        dissemination information it manages. The NVA can obtain information
        either from the VM orchestration system, and/or directly from the NVEs
        themselves.</t>

        <t>On virtualized systems, the NVA may be able to obtain the address
        mapping information associated with VMs from the VM orchestration
        system itself. If the VM orchestration system contains a master
        database for all the virtualization information, having the NVA obtain
        information directly to the orchestration system would be a natural
        approach. Indeed, the NVA could effectively be co-located with the VM
        orchestration system itself. In such systems, the VM orchestration
        system communicates with the NVE indirectly through the
        hypervisor.</t>

        <t>However, as described in <xref target="nve-section2"/> not all NVEs
        are associated with hypervisors. In such cases, NVAs cannot leverage
        VM orchestration protocols to interact with an NVE and will instead
        need to peer directly with them. By peering directly with an NVE, NVAs
        can obtain information about the TSs connected to that NVE and can
        distribute information to the NVE about the VNs those TSs are
        associated with. For example, whenever a Tenant System attaches to an
        NVE, that NVE would notify the NVA that the TS is now associated with
        that NVE. Likewise when a TS detaches from an NVE, that NVE would
        inform the NVA. By communicating directly with NVEs, both the NVA and
        the NVE are able to maintain up-to-date information about all active
        tenants and the NVEs to which they are attached.</t>
      </section>

      <section title="Internal NVA Architecture">
        <t>For reliability and fault tolerance reasons, an NVA would be
        implemented in a distributed or replicated manner without single
        points of failure. How the NVA is implemented, however, is not
        important to an NVE so long as the NVA provides a consistent and
        well-defined interface to the NVE. For example, an NVA could be
        implemented via database techniques whereby a server stores address
        mapping information in a traditional (possibly replicated) database.
        Alternatively, an NVA could be implemented in a distributed fashion
        using an existing (or modified) routing protocol to maintain and
        distribute mappings. So long as there is a clear interface between the
        NVE and NVA, how an NVA is architected and implemented is not
        important to an NVE.</t>

        <t>A number of architectural approaches could be used to implement
        NVAs themselves. NVAs manage address bindings and distribute them to
        where they need to go. One approach would be to use Border Gateway
        Protocol (BGP) <xref target="RFC4364"/> (possibly with extensions) and
        route reflectors. Another approach could use a transaction-based
        database model with replicated servers. Because the implementation
        details are local to an NVA, there is no need to pick exactly one
        solution technology, so long as the external interfaces to the NVEs
        (and remote NVAs) are sufficiently well defined to achieve
        interoperability.</t>
      </section>

      <section title="NVA External Interface">
        <t>Conceptually, from the perspective of an NVE, an NVA is a single
        entity. An NVE interacts with the NVA, and it is the NVA's
        responsibility for ensuring that interactions between the NVE and NVA
        result in consistent behavior across the NVA and all other NVEs using
        the same NVA. Because an NVA is built from multiple internal
        components, an NVA will have to ensure that information flows to all
        internal NVA components appropriately.</t>

        <t>One architectural question is how the NVA presents itself to the
        NVE. For example, an NVA could be required to provide access via a
        single IP address. If NVEs only have one IP address to interact with,
        it would be the responsibility of the NVA to handle NVA component
        failures, e.g., by using a "floating IP address" that migrates among
        NVA components to ensure that the NVA can always be reached via the
        one address. Having all NVA accesses through a single IP address,
        however, adds constraints to implementing robust failover, load
        balancing, etc.</t>

        <t>In the NVO3 architecture, an NVA is accessed through one or more IP
        addresses (or IP address/port combination). If multiple IP addresses
        are used, each IP address provides equivalent functionality, meaning
        that an NVE can use any of the provided addresses to interact with the
        NVA. Should one address stop working, an NVE is expected to failover
        to another. While the different addresses result in equivalent
        functionality, one address may respond more quickly than another,
        e.g., due to network conditions, load on the server, etc.</t>

        <t>To provide some control over load balancing, NVA addresses may have
        an associated priority. Addresses are used in order of priority, with
        no explicit preference among NVA addresses having the same priority.
        To provide basic load-balancing among NVAs of equal priorities, NVEs
        could use some randomization input to select among equal-priority
        NVAs. Such a priority scheme facilitates failover and load balancing,
        for example, allowing a network operator to specify a set of primary
        and backup NVAs.</t>

        <t>It may be desirable to have individual NVA addresses responsible
        for a subset of information about an NV Domain. In such a case, NVEs
        would use different NVA addresses for obtaining or updating
        information about particular VNs or TS bindings. A key question with
        such an approach is how information would be partitioned, and how an
        NVE could determine which address to use to get the information it
        needs.</t>

        <t>Another possibility is to treat the information on which NVA
        addresses to use as cached (soft-state) information at the NVEs, so
        that any NVA address can be used to obtain any information, but NVEs
        are informed of preferences for which addresses to use for particular
        information on VNs or TS bindings. That preference information would
        be cached for future use to improve behavior - e.g., if all requests
        for a specific subset of VNs are forwarded to a specific NVA
        component, the NVE can optimize future requests within that subset by
        sending them directly to that NVA component via its address.</t>
      </section>
    </section>

    <section anchor="nve-to-nva" title="NVE-to-NVA Protocol">
      <t>As outlined in <xref target="nve-state"/>, an NVE needs certain
      information in order to perform its functions. To obtain such
      information from an NVA, an NVE-to-NVA protocol is needed. The
      NVE-to-NVA protocol provides two functions. First it allows an NVE to
      obtain information about the location and status of other TSs with which
      it needs to communicate. Second, the NVE-to-NVA protocol provides a way
      for NVEs to provide updates to the NVA about the TSs attached to that
      NVE (e.g., when a TS attaches or detaches from the NVE), or about
      communication errors encountered when sending traffic to remote NVEs.
      For example, an NVE could indicate that a destination it is trying to
      reach at a destination NVE is unreachable for some reason.</t>

      <t>While having a direct NVE-to-NVA protocol might seem straightforward,
      the existence of existing VM orchestration systems complicates the
      choices an NVE has for interacting with the NVA.</t>

      <section title="NVE-NVA Interaction Models">
        <t>An NVE interacts with an NVA in at least two (quite different)
        ways:</t>

        <t><list style="symbols">
            <t>NVEs embedded within the same server as the hypervisor can
            obtain necessary information entirely through the
            hypervisor-facing side of the NVE. Such an approach is a natural
            extension to existing VM orchestration systems supporting server
            virtualization because an existing protocol between the hypervisor
            and VM orchestration system already exists and can be leveraged to
            obtain any needed information. Specifically, VM orchestration
            systems used to create, terminate and migrate VMs already use
            well-defined (though typically proprietary) protocols to handle
            the interactions between the hypervisor and VM orchestration
            system. For such systems, it is a natural extension to leverage
            the existing orchestration protocol as a sort of proxy protocol
            for handling the interactions between an NVE and the NVA. Indeed,
            existing implementations can already do this.</t>

            <t>Alternatively, an NVE can obtain needed information by
            interacting directly with an NVA via a protocol operating over the
            data center underlay network. Such an approach is needed to
            support NVEs that are not associated with systems performing
            server virtualization (e.g., as in the case of a standalone
            gateway) or where the NVE needs to communicate directly with the
            NVA for other reasons.</t>
          </list></t>

        <t>The NVO3 architecture will focus on support for the second model
        above. Existing virtualization environments are already using the
        first model. But they are not sufficient to cover the case of
        standalone gateways -- such gateways may not support virtualization
        and do not interface with existing VM orchestration systems.</t>
      </section>

      <section title="Direct NVE-NVA Protocol">
        <t>An NVE can interact directly with an NVA via an NVE-to-NVA
        protocol. Such a protocol can be either independent of the NVA
        internal protocol, or an extension of it. Using a purpose-specific
        protocol would provide architectural separation and independence
        between the NVE and NVA. The NVE and NVA interact in a well-defined
        way, and changes in the NVA (or NVE) do not need to impact each other.
        Using a dedicated protocol also ensures that both NVE and NVA
        implementations can evolve independently and without dependencies on
        each other. Such independence is important because the upgrade path
        for NVEs and NVAs is quite different. Upgrading all the NVEs at a site
        will likely be more difficult in practice than upgrading NVAs because
        of their large number - one on each end device. In practice, it would
        be prudent to assume that once an NVE has been implemented and
        deployed, it may be challenging to get subsequent NVE extensions and
        changes implemented and deployed, whereas an NVA (and its associated
        internal protocols) are more likely to evolve over time as experience
        is gained from usage and upgrades will involve fewer nodes.</t>

        <t>Requirements for a direct NVE-NVA protocol can be found in <xref
        target="I-D.ietf-nvo3-nve-nva-cp-req"/></t>
      </section>

      <section title="Propagating Information Between NVEs and NVAs">
        <t>Information flows between NVEs and NVAs in both directions. The NVA
        maintains information about all VNs in the NV Domain, so that NVEs do
        not need to do so themselves. NVEs obtain from the NVA information
        about where a given remote TS destination resides. NVAs in turn obtain
        information from NVEs about the individual TSs attached to those
        NVEs.</t>

        <t>While the NVA could push information relevant to every virtual
        network to every NVE, such an approach scales poorly and is
        unnecessary. In practice, a given NVE will only need and want to know
        about VNs to which it is attached. Thus, an NVE should be able to
        subscribe to updates only for the virtual networks it is interested in
        receiving updates for. The NVO3 architecture supports a model where an
        NVE is not required to have full mapping tables for all virtual
        networks in an NV Domain.</t>

        <t>Before sending unicast traffic to a remote TS (or TSes for
        broadcast or multicast traffic), an NVE must know where the remote
        TS(es) currently reside. When a TS attaches to a virtual network, the
        NVE obtains information about that VN from the NVA. The NVA can
        provide that information to the NVE at the time the TS attaches to the
        VN, either because the NVE requests the information when the attach
        operation occurs, or because the VM orchestration system has initiated
        the attach operation and provides associated mapping information to
        the NVE at the same time.</t>

        <t>There are scenarios where an NVE may wish to query the NVA about
        individual mappings within an VN. For example, when sending traffic to
        a remote TS on a remote NVE, that TS may become unavailable (e.g,.
        because it has migrated elsewhere or has been shutdown, in which case
        the remote NVE may return an error indication). In such situations,
        the NVE may need to query the NVA to obtain updated mapping
        information for a specific TS, or verify that the information is still
        correct despite the error condition. Note that such a query could also
        be used by the NVA as an indication that there may be an inconsistency
        in the network and that it should take steps to verify that the
        information it has about the current state and location of a specific
        TS is still correct.</t>

        <t>For very large virtual networks, the amount of state an NVE needs
        to maintain for a given virtual network could be significant.
        Moreover, an NVE may only be communicating with a small subset of the
        TSs on such a virtual network. In such cases, the NVE may find it
        desirable to maintain state only for those destinations it is actively
        communicating with. In such scenarios, an NVE may not want to maintain
        full mapping information about all destinations on a VN. Should it
        then need to communicate with a destination for which it does not have
        mapping information, however, it will need to be able to query the NVA
        on demand for the missing information on a per-destination basis.</t>

        <t>The NVO3 architecture will need to support a range of operations
        between the NVE and NVA. Requirements for those operations can be
        found in <xref target="I-D.ietf-nvo3-nve-nva-cp-req"/>.</t>
      </section>
    </section>

    <section title="Federated NVAs">
      <t>An NVA provides service to the set of NVEs in its NV Domain. Each NVA
      manages network virtualization information for the virtual networks
      within its NV Domain. An NV domain is administered by a single
      entity.</t>

      <t>In some cases, it will be necessary to expand the scope of a specific
      VN or even an entire NV domain beyond a single NVA. For example,
      multiple data centers managed by the same administrator may wish to
      operate all of its data centers as a single NV region. Such cases are
      handled by having different NVAs peer with each other to exchange
      mapping information about specific VNs. NVAs operate in a federated
      manner with a set of NVAs operating as a loosely-coupled federation of
      individual NVAs. If a virtual network spans multiple NVAs (e.g., located
      at different data centers), and an NVE needs to deliver tenant traffic
      to an NVE that is part of a different NV Domain, it still interacts only
      with its NVA, even when obtaining mappings for NVEs associated with a
      different NV Domain.</t>

      <t><xref target="nva-federation"/> shows a scenario where two separate
      NV Domains (1 and 2) share information about Virtual Network "1217". VM1
      and VM2 both connect to the same Virtual Network 1217, even though the
      two VMs are in separate NV Domains. There are two cases to consider. In
      the first case, NV Domain B (NVB) does not allow NVE-A to tunnel traffic
      directly to NVE-B. There could be a number of reasons for this. For
      example, NV Domains 1 and 2 may not share a common address space (i.e.,
      require traversal through a NAT device), or for policy reasons, a domain
      might require that all traffic between separate NV Domains be funneled
      through a particular device (e.g., a firewall). In such cases, NVA-2
      will advertise to NVA-1 that VM1 on Virtual Network 1217 is available,
      and direct that traffic between the two nodes go through IP-G. IP-G
      would then decapsulate received traffic from one NV Domain, translate it
      appropriately for the other domain and re-encapsulate the packet for
      delivery.</t>

      <figure anchor="nva-federation"
              title="VM1 and VM2  are in          different NV Domains.">
        <artwork name="nve-reference-model"><![CDATA[
                 xxxxxx                          xxxx        +-----+
+-----+     xxxxxx    xxxxxx               xxxxxx    xxxxx   | VM2 |
| VM1 |    xx              xx            xxx             xx  |-----|
|-----|   xx                x          xx                 x  |NVE-B|
|NVE-A|   x                 x  +----+  x                   x +-----+
+--+--+   x   NV Domain A   x  |IP-G|--x                    x    |  
   +-------x               xx--+    | x                     xx   |  
           x              x    +----+ x     NV Domain B      x   |  
        +---x           xx            xx                     x---+  
        |    xxxx      xx           +->xx                   xx      
        |       xxxxxxxx            |   xx                 xx       
    +---+-+                         |     xx              xx        
    |NVA-1|                      +--+--+    xx         xxx          
    +-----+                      |NVA-2|     xxxx   xxxx            
                                 +-----+        xxxxx               
      ]]></artwork>
      </figure>

      <t>NVAs at one site share information and interact with NVAs at other
      sites, but only in a controlled manner. It is expected that policy and
      access control will be applied at the boundaries between different sites
      (and NVAs) so as to minimize dependencies on external NVAs that could
      negatively impact the operation within a site. It is an architectural
      principle that operations involving NVAs at one site not be immediately
      impacted by failures or errors at another site. (Of course,
      communication between NVEs in different NV domains may be impacted by
      such failures or errors.) It is a strong requirement that an NVA
      continue to operate properly for local NVEs even if external
      communication is interrupted (e.g., should communication between a local
      and remote NVA fail).</t>

      <t>At a high level, a federation of interconnected NVAs has some
      analogies to BGP and Autonomous Systems. Like an Autonomous System, NVAs
      at one site are managed by a single administrative entity and do not
      interact with external NVAs except as allowed by policy. Likewise, the
      interface between NVAs at different sites is well defined, so that the
      internal details of operations at one site are largely hidden to other
      sites. Finally, an NVA only peers with other NVAs that it has a trusted
      relationship with, i.e., where a VN is intended to span multiple
      NVAs.</t>

      <t>Reasons for using a federated model include: <list style="symbols">
          <t>Provide isolation among NVAs operating at different sites at
          different geographic locations.</t>

          <t>Control the quantity and rate of information updates that flow
          (and must be processed) between different NVAs in different data
          centers.</t>

          <t>Control the set of external NVAs (and external sites) a site
          peers with. A site will only peer with other sites that are
          cooperating in providing an overlay service.</t>

          <t>Allow policy to be applied between sites. A site will want to
          carefully control what information it exports (and to whom) as well
          as what information it is willing to import (and from whom).</t>

          <t>Allow different protocols and architectures to be used to for
          intra- vs. inter-NVA communication. For example, within a single
          data center, a replicated transaction server using database
          techniques might be an attractive implementation option for an NVA,
          and protocols optimized for intra-NVA communication would likely be
          different from protocols involving inter-NVA communication between
          different sites.</t>

          <t>Allow for optimized protocols, rather than using a one-size-fits
          all approach. Within a data center, networks tend to have
          lower-latency, higher-speed and higher redundancy when compared with
          WAN links interconnecting data centers. The design constraints and
          tradeoffs for a protocol operating within a data center network are
          different from those operating over WAN links. While a single
          protocol could be used for both cases, there could be advantages to
          using different and more specialized protocols for the intra- and
          inter-NVA case.</t>
        </list></t>

      <section title="Inter-NVA Peering">
        <t>To support peering between different NVAs, an inter-NVA protocol is
        needed. The inter-NVA protocol defines what information is exchanged
        between NVAs. It is assumed that the protocol will be used to share
        addressing information between data centers and must scale well over
        WAN links.</t>
      </section>
    </section>

    <section title="Control Protocol Work Areas">
      <t>The NVO3 architecture consists of two major distinct entities: NVEs
      and NVAs. In order to provide isolation and independence between these
      two entities, the NVO3 architecture calls for well defined protocols for
      interfacing between them. For an individual NVA, the architecture calls
      for a logically centralized entity that could be implemented in a
      distributed or replicated fashion. While the IETF may choose to define
      one or more specific architectural approaches to building individual
      NVAs, there is little need for it to pick exactly one approach to the
      exclusion of others. An NVA for a single domain will likely be deployed
      as a single vendor product and thus there is little benefit in
      standardizing the internal structure of an NVA.</t>

      <t>Individual NVAs peer with each other in a federated manner. The NVO3
      architecture calls for a well-defined interface between NVAs.</t>

      <t>Finally, a hypervisor-to-NVE protocol is needed to cover the
      split-NVE scenario described in <xref target="split-nve"/>.</t>
    </section>

    <section title="NVO3 Data Plane Encapsulation">
      <t>When tunneling tenant traffic, NVEs add encapsulation header to the
      original tenant packet. The exact encapsulation to use for NVO3 does not
      seem to be critical. The main requirement is that the encapsulation
      support a Context ID of sufficient size. A number of encapsulations
      already exist that provide a VN Context of sufficient size for NVO3. For
      example, VXLAN <xref target="RFC7348"/> has a 24-bit VXLAN Network
      Identifier (VNI). NVGRE <xref target="RFC7637"/> has a 24-bit Tenant
      Network ID (TNI). MPLS-over-GRE provides a 20-bit label field. While
      there is widespread recognition that a 12-bit VN Context would be too
      small (only 4096 distinct values), it is generally agreed that 20 bits
      (1 million distinct values) and 24 bits (16.8 million distinct values)
      are sufficient for a wide variety of deployment scenarios.</t>
    </section>

    <section title="Operations, Administration and Maintenance (OAM)">
      <t>The simplicity of operating and debugging overlay networks will be
      critical for successful deployment.</t>

      <t>Overlay networks are based on tunnels between NVEs, so the OAM
      (Operations, Administration and Maintenance) <xref target="RFC6291"/>
      framework for overlay networks can draw from prior IETF OAM work for
      tunnel-based networks, specifically L2VPN OAM <xref target="RFC6136"/>.
      RFC 6136 focuses on Fault Management and Performance Management as
      fundamental to L2VPN service delivery, leaving the Configuration,
      Management, Accounting Management and Security Management components of
      the OSI "FCAPS" taxonomy <xref target="M.3400"/> for further study. This
      section does likewise for NVO3 OAM, but those three areas continue to be
      important parts of complete OAM functionality for NVO3.</t>

      <t>As is the case for L2VPN, there is a client/server relationship
      between the overlay and underlay networks that is a consideration for
      fault and performance management - a fault in the underlay may manifest
      as fault and/or performance issues in the overlay. Diagnosing and fixing
      such issues are complicated by NVO3 abstracting the underlay network
      away from the overlay network (e.g., intermediate nodes on the underlay
      network path between NVEs are hidden from overlay VNs).</t>

      <t>NVO3-specific OAM techniques, protocol constructs and tools are
      needed to provide visibility beyond this abstraction to diagnose and
      correct problems that appear in the overlay. Two examples are
      underlay-aware traceroute <xref
      target="I-D.nordmark-nvo3-transcending-traceroute"/>, and ping protocol
      constructs for overlay networks <xref
      target="I-D.jain-nvo3-vxlan-ping"/> <xref
      target="I-D.kumar-nvo3-overlay-ping"/>.</t>

      <t>NVO3-specific tools and techniques are best viewed as complements to
      (i.e., not as replacements for) single-network tools that apply to the
      overlay and/or underlay networks. Coordination among the individual
      network tools (for the overlay and underlay networks) and NVO3-aware
      dual-network tools is required to achieve effective monitoring and fault
      diagnosis. For example, the defect detection intervals and performance
      measurement intervals ought to be coordinated among all tools involved
      in order to provide consistency and comparability of results.</t>

      <t>For further discussion of NVO3 OAM requirements, see <xref
      target="I-D.ashwood-nvo3-oam-requirements"/>.</t>
    </section>

    <section title="Summary">
      <t>This document presents the overall architecture for Network
      Virtualization Overlays (NVO3). The architecture calls for three main
      areas of protocol work:</t>

      <t><list style="numbers">
          <t>A hypervisor-to-NVE protocol to support Split NVEs as discussed
          in <xref target="split-nve"/>.</t>

          <t>An NVE to NVA protocol for disseminating VN information (e.g.,
          inner to outer address mappings).</t>

          <t>An NVA-to-NVA protocol for exchange of information about specific
          virtual networks between federated NVAs.</t>
        </list></t>

      <t>It should be noted that existing protocols or extensions of existing
      protocols are applicable.</t>
    </section>

    <section anchor="Acknowledgments" title="Acknowledgments">
      <t>Helpful comments and improvements to this document have come from
      Alia Atlas, Abdussalam Baryun, Linda Dunbar, Lizhong Jin, Anton Ivanov,
      Greg Mirsky, Carlos Pignataro, Dennis (Xiaohong) Qin, Erik Smith,
      Takeshi Takahashi, Ziye Yang and Lucy Yong.</t>
    </section>

    <!-- Possibly a 'Contributors' section ... -->

    <section anchor="IANA" title="IANA Considerations">
      <t>This memo includes no request to IANA.</t>
    </section>

    <section anchor="Security" title="Security Considerations">
      <t>The data plane and control plane described in this architecture will
      need to address potential security threats.</t>

      <t>For the data plane, tunneled application traffic may need protection
      against being misdelivered, modified, or having its content exposed to
      an inappropriate third party. In all cases, encryption between
      authenticated tunnel endpoints (e.g., via use of <xref
      target="RFC4301">IPsec</xref>) and enforcing policies that control which
      endpoints and VNs are permitted to exchange traffic can be used to
      mitigate risks.</t>

      <t>For the control plane, between NVAs, the NVA and NVE as well as
      between different components of the split-NVE approach, a combination of
      authentication and encryption can be used. All entities will need to
      properly authenticate with each other and enable encryption for their
      interactions as appropriate to protect sensitive information.</t>

      <t>Leakage of sensitive information about users or other entities
      associated with VMs whose traffic is virtualized can also be covered by
      using encryption for the control plane protocols and enforcing policies
      that control which NVO3 components are permitted to exchange control
      plane traffic.</t>

      <t>See the NVO3 framework security considerations in <xref
      target="RFC7365">RFC 7365</xref> for further discussion.</t>
    </section>
  </middle>

  <!-- *****BACK MATTER ***** -->

  <back>
    <!-- References split into informative and normative -->

    <!-- There are 2 ways to insert reference entries from the citation libraries:
	 1. define an ENTITY at the top, and use "ampersand character"RFC2629; here (as shown)
	 2. simply use a PI "less than character"?rfc include="reference.RFC.2119.xml"?> here
(for I-Ds: include="reference.I-D.narten-iana-considerations-rfc2434bis.xml")

Both are cited textually in the same manner: by using xref elements.
If you use the PI option, xml2rfc will, by default, try to find included files in the same
directory as the including file. You can also define the XML_LIBRARY environment variable
with a value containing a set of directories to search.  These can be either in the local
filing system or remote ones accessed by http (http://domain/dir/... ).-->

    <references title="Informative References">
      <!-- Here we use entities that we defined at the beginning. -->

      <?rfc include="reference.I-D.ashwood-nvo3-oam-requirements" ?>

      <?rfc include="reference.I-D.ietf-nvo3-nve-nva-cp-req" ?>

      <?rfc include="reference.I-D.ietf-nvo3-mcast-framework" ?>

      <?rfc include="reference.I-D.jain-nvo3-vxlan-ping" ?>

      <?rfc include="reference.I-D.kumar-nvo3-overlay-ping" ?>

      <?rfc include="reference.I-D.nordmark-nvo3-transcending-traceroute" ?>

      <?rfc include="reference.RFC.7637" ?>

      <?rfc include="reference.RFC.7348" ?>

      <?rfc include="reference.RFC.7364" ?>

      <?rfc include="reference.RFC.7365" ?>

      <?rfc include="reference.RFC.4364" ?>

      <?rfc include="reference.RFC.4861" ?>

      <?rfc include="reference.RFC.0826" ?>

      <?rfc include="reference.RFC.6291" ?>

      <?rfc include="reference.RFC.6136" ?>

      <?rfc include="reference.RFC.4301" ?>

      <reference anchor="IEEE-802.1Q">
        <front>
          <title>IEEE Standard for Local and metropolitan area networks:
          Bridges and Bridged Networks</title>

          <author fullname="" surname="IEEE Std 802.1Q-2014"/>

          <date month="November" year="2014"/>
        </front>

        <format target="http://standards.ieee.org/getieee802/download/802-1Q-2014.pdf"
                type="pdf"/>
      </reference>

      <reference anchor="M.3400">
        <front>
          <title>TMN management functions</title>

          <author surname="ITU-T Recommendation M.3400"/>

          <date month="February" year="2000"/>
        </front>

        <format target="https://www.itu.int/rec/T-REC-M.3400-200002-I/"
                type="pdf"/>
      </reference>
    </references>
  </back>
</rfc>